PROBLEM
It was seen recently on a T7000 whereby an Intel S2600TP system that boots and the only thing on the screen is the following with the number 26 in the lower right corner.
Text on the screen reads as:
Board Name S2600TP
Chipset initialization complete. No errors found.
26 (lower right hand corner).
CAUSE
I filed case 00556496 with Intel and the results were as follows:
POST code 26 indicates it may hang on to the Memory Reference Phrase (MRC) phase as MRC training is a failure. In this scenario, we recommend changing other DIMMs or boards. |
SOLUTION
Replace the Memory, or since if Memory is not FRU, replace the controller.
ADDITIONAL INFORMATION
For additional information on other codes, see: S2600TP Intel Troubleshooting Guide